• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MULTIPLE-UNIT OPERATION
MULTIPLE-UNIT OPERATION (cont) - TM-55-2210-223-12_68

TM-55-2210-223-12 Oil-Water Separtor 5 GPM Type Seprator 5 GPM Type A 3 Stage NSN 2090-010-076-5849 Manual
Page Navigation
  53    54    55    56    57  58  59    60    61    62    63  
TM 55-2210-223-12 TO 45A2-2-14-41 2-29.  MULTIPLE-UNIT OPERATION (cont) c. Starting. NOTE Ensure the PMCS has been performed on both units. (1) Determine which locomotive is to be the trailing unit and, if not already started, start in accordance with paragraphs 2-10 and 2-11. (2) Set controls on trailing unit as follows: (a) REMOTE HDLTSWITCH (1) to position 4. (b) Isolation  switch  (2)  to  RUN.    If  the  unit  is  not required to deliver power, set isolation switch to IDLE. (c) GF switch (3) to ON. (d) Throttle handle (4) to IDLE. (e) Reverser  handle  (5)  to  NEUTRAL  position  and remove handle. (f) Independent    brake    valve    (6)    to    RELEASE position    and    automatic    brake    valve    (7)    to HANDLE-OFF position.  Remove both handles. (g) Double-ported    cutout    cock    (8)    to    CLOSED position. (h) Cutoff pilot valve (9) to OUT. (i) Release handbrake (10). (3) Return to lead locomotive and, if not already started, start in accordance with paragraphs 2-10 and 2-11. (4) Set REMOTE HDLTSWITCH (1) to position 2 or 3. 2-43