TM 55-2210-224-34
3-28. REVERSER
This task covers:
a.
Removal
c.
Cleaning
e.
Repair
g.
Installation
b.
Disassembly
d.
Inspection
f.
Assembly
h.
Test
INITIAL SETUP
Tools
Material/Parts
Tool kit SC4940-97-CL-E12
Drycleaning solvent (Item 34, Appendix B)
Test Equipment
Variable dc voltage supply
REMOVAL
WARNING
· High voltage is use in the operation of
equipment. Do not be misled by the
term LOW VOLTAGE. Potentials as
low as 50 volts may cause death.
· Remove
rings,
bracelets,
wristwatches, and neck chains before
working
around
the
locomotive.
Jewelry can catch on equipment and
cause injury, or may short across an
electrical circuit and cause severe
burns or electrical shock.
1. Open electrical equipment cabinet door and set
battery switch to OPEN. Make sure that electrical
wires are labeled with wire numbers or polarity
signs. Disconnect wires from reverser (7).
2. Disconnect air line fittings (1).
3. Remove four nuts (2), lockwashers (3), flat
washers (4), capscrews (5), flat washers (6), and
reverser (7).
3-114