TM 55-2210-223-12
TO 45A2-2-14-41
4-18. ELECTRICAL EQUIPMENT CABINET DOOR (cont)
CLEANING, INSPECTION, AND REPAIR
WARNING
Dry-cleaning
solvent
P-D-680
is
toxic
and
flammable. Wear protective goggles and gloves and
use only in a well-ventilated area. Avoid contact
with skin, eyes, and clothes and don't breathe
vapors. Do not use near open flame or excessive
heat. The flash point is 100 - 138°F (38 - 59°C). If
you become dizzy, get fresh air and medical aid
immediately. If contact with eyes is made, wash
your eyes and get medical aid immediately.
4.
Clean parts with dry-cleaning solvent.
5.
Inspect parts for cracks, breaks, and damage.
6.
Inspect lock and handle for serviceability.
7.
Repair consists of replacement of damaged parts.
ASSEMBLY
8.
If removed, weld hinges (7) to door (2) and compartment cabinet.
9.
Position two lock and handles (6) in door (2) and install eight screws (5), lockwashers (4), and nuts (3).
INSTALLATION
10.
Position door (2) on compartment cabinet and install pins (1).
4-38