TM 55-2210-223-34
TO 45A2-2-14-22
3-62. TRACTION MOTOR ASSEMBLY (cont)
CLEANING, INSPECTION, AND REPAIR (cont)
39. Check that traction motor leads to stator housing are tight and secure. Replace insulation that is cracked or brittle
with three layers of friction tape using 1/2 inch (12.7 mm) lap. Paint with black air drying insulation paint.
40. Clean, inspect, and repair remaining parts by the following:
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well-ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not
use near open flame or excessive heat. The flash point is 100-138°F (38-59°C). If you become dizzy,
get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes and get
medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Do not direct compressed
air against skin. Use goggles or full face shield.
a. Use drycleaning solvent and clean parts. Dry with compressed air.
b. Inspect parts for cracks or breaks.
c. Replace defective parts.
CAUTION
Do not paint machined surfaces.
d. Paint inside surface of traction motor covers with red enamel insulating varnish.
e. Paint outside surface of traction motor frame with black air drying insulating paint.
3-239