30. BATTERIES FAIL TO CHARGE. (cont)
Step 4. Check to see if the battery charging resistors RE70 are working properly.
Test and replace resistors RE70 (para 3-31).
Step 5. Check to see if battery fuse F3 is blown.
Test and replace fuse F3 (TM 55-2210-223-12).
Step 6. Check to see if the auxiliary generator fuse F2 is blown.
Test and replace auxiliary generator fuse F2 (TM 55-2210-223-12).
Step 7. Check to see if start switch S2 contacts transfer.
Test and replace start switch S2 (TM 55-2210-223-12).
COOLING SYSTEM
31. COOLANT TEMPERATURE IS EXCESSIVE.
Step 1. Check for broken coolant pump shaft or impeller.
Repair or replace pump (TM 5-2815-232-14).
Step 2. Check for faulty shutter operation.
Repair for proper operation (para 3-40).
Step 3. Check for faulty water pump operation.
Repair or replace water pump (TM 5-2815-232-14).
Step 4. Check for faulty fan operation.
Repair or replace fan (para 3-41).
Step 5. Check to see if thermostat (water temperature regulator) is stuck.
Repair or replace thermostat (water temperature regulator) (TM 5-2815-232-14).
Step 6. Check to see if oil cooler is plugged.
Unplug oil cooler (TM 5-2815-232-14).