TM 55-2210-224-34
3-37.
MAIN GENERATOR (cont)
CLEANING, INSPECTION, AND REPAIR (cont)
e.
Inspect spring assemblies for tension and check that braiding is not frayed. Replace defective spring
assemblies.
CAUTION
Do not spray brush contact area.
f.
Paint brush holders with clear acrylic lacquer.
27. Clean, inspect, and repair ring assembly by the following:
a.
Check that insulation is not cracked or blistered.
b.
Check that fiberglass rings are not cracked or broken.
CAUTION
Do not paint gasket surfaces.
c.
Paint assembly with electrical insulating varnish.
28. Clean, inspect, and repair remaining parts by the following:
WARNING
· Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use only in a well-ventilated area. Avoid contact with skin, eyes,
and clothes and don't breathe vapors. Do not use near open flame or excessive
heat. The flash point is 100 138°F (38 59°C). If you become dizzy, get fresh air
immediately and get medical aid. If contact with eyes is made, wash your eyes
and get medical aid immediately.
· Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).
Do not direct compressed air against skin. Use goggles or full face shield.
a.
Use drycleaning solvent and clean parts. Dry with compressed air.
b.
Inspect parts for cracks or breaks.
c.
Replace defective parts.
3-155