4-11. AUTOMATIC BRAKE VALVE (cont)
CLEANING, INSPECTION, AND REPAIR
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat.
The flash point is 100 138°F (38 59°C). If you become dizzy, get fresh air and
medical aid immediately. If contact with eyes is made, wash your eyes and get
medical aid immediately.
41. Use a cloth dampened with dry-cleaning solvent and remove grease and oil from exterior of cam housing (22) and
brake valve body (23).
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Do
not direct compressed air against skin. Use goggles or full face shield.
42. Use dry-cleaning solvent and clean metal parts. Dry with compressed air.
43. Inspect metal parts for cracks, breaks, cuts, or other damage. Replace damaged parts.
44. Check that springsare not rusted, distorted, or have taken a permanent set. Replace damaged springs.
45. Refinish faces of rubber check valves by lapping on a piece of medium weight emery paper.
4-42