4-19. CUTOUT COCK AND STRAINER
CLEANING, INSPECTION, AND REPAIR
WARNING
l Drycleaning solvent P-D-680 is toxic and flammable. Wear
protective goggles and gloves and use only in a well-ventilated
area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat.
The flash point is 100 138°F (38 59°C). If you become dizzy, get
fresh air and medical aid immediately. If contact with eyes is
made, wash your eyes and get medical aid immediately.
l Compressed air used for cleaning purposes will not exceed 30
psi (207 kPa). Do not direct compressed air against skin. Use
goggles or full face shield.
5.
Use a cloth dampened in drycleaning solvent and remove grease and oil from exterior and interior of body (18).
6.
Use drycleaning solvent and clean metal parts. Dry with compressed air.
7.
Inspect metal parts for cracks, breaks, cuts, or other damage.
8.
Check that spring (10) has not rusted, become distorted, or has taken a permanent set.
9.
Replace damaged parts. Replace filter (4).
ASSEMBLY
10.
Position gasket (17) on sump cover (16). Position body (18) and install two bolts (15) and nuts (14).
11.
Install O-ring (13) on key (12) and install key in body (18).
12.
Install flat washer (11) and spring (10) on key (12).
13.
Position gasket (9) on cover (8). Position cover on body (18) and install two bolts (7).
14.
Position handle (6) and install pin (5).
15.
Install filter (4) in body (18).
16.
Position gasket (3) on strainer cover (2). Position cover on body (18) and install four bolts (1).
4-98