TM 55-2210-224-34
3-22. FIELD SHUNT CONTACTOR (cont)
DISASSEMBLY (cont)
9.
Loosen calibrating screw locknut (27) and remove calibrating screw (28), flat washer (29), spacer (30), calibrating
screw locknut, star washer (31), and calibrating spring (32).
10. Remove cotter pin (33), spring seat (34), and contact pressure spring (35). Remove two caps
crews (36), lockwasher
(37), pins (38), clamps (39), and flat washers (40). Remove contact lever (41) from armature (42). Remove
armature from armature stop (45).
11. Remove two capscrews (43) and lockwashers (44). Remove armature stop (45).
12. Remove capscrew (46), lockwasher (47), and operating coil (48). Remove two capscrews (49), lockwashers (50),
flat washers (51), and magnet frame (52) from base (53).
3-69