TM 55-2210-223-34
TO 45A2-2-14-22
3-10. TEMPERATURE GAGE
This task covers:
a.
Removal
b.
Test
c.
Installation
INITIAL SETUP
Tools
Tool kit SC 4940-97-CL-E12
REMOVAL
1.
Disconnect capillary tubing (1) from engine block.
2.
Remove two nuts (2), lockwashers (3), and retainer bracket (4). Remove temperature gage (5).
TEST
NOTE
If it is suspected that gage is defective remove and test gage.
3.
Heat water vat to 180°F (82°C). Check with thermometer.
4.
Place bulb in vat. If gage does not indicate 180°F (82°C), replace gage.
INSTALLATION
5.
Install temperature gage (5) on control stand and secure with retainer bracket (4), two lockwashers (3), and
nuts (2).
6.
Connect capillary tubing (1) to engine water manifold on left top of engine.
3-44