TM 55-2210-224-34
3-23. CRANKING CONTACTOR (cont)
INSTALLATION
30. Position cranking contactor assembly (3) in high-voltage cabinet and install two lockwashers (2) and capscrews (1).
31. Connect electrical wires in accordance with wiring diagram and remove tags.
ADJUSTMENT
32. Measure contact tip overtravel as follows:
NOTE
Overtravel is the distance a movable contact tip would travel after
touching the stationary tip if the stationary tip were then removed.
a.
Measure overtravel by either method 1, pin at A, or method 2, pin at B. Consult table 3-
2 for amount of
overtravel and size of pin required to measure that amount.
3-85