4-31. MULTIPLE-UNIT CONTROL JUMPER
This task covers:
a.
Test
b.
Removal
c.
Installation
INITIAL SETUP:
Tools
Test Equipment
Tool kit SC4940-97-CL-E16
Multimeter 6625-01-139-2512
TEST
1.
Ensure terminal contacts are not burned, corroded, or broken.
2.
Use multimeter and test for continuity.
REMOVAL
3.
Remove multiple-unit control (1) jumper from
receptacle.
4.
Remove two nuts (2), lockwashers (3), screws (4),
and clamp (5). Remove multiple-unit control jumper
(1).
INSTALLATION
5.
Position multiple-unit control jumper (1) in clamp (5).
Install two screws (4), lockwashers (3), and nuts (2).
6.
Plug multiple-unit control jumper (1) in receptacle.
4-77