TM 55-2210-223-12
TO 45A2-2-14-41
4-33. ENGINE COMPARTMENT CONVENIENCE RECEPTACLE
This task covers:
a.
Test
b.
Removal
c.
Installation
INITIAL SETUP:
Tools
Test Equipment
Tool kit SC4940-97-CL-E16
Multimeter 6625-01-139-2512
TEST
WARNING
Remove rings, bracelets, wristwatches, and neck
chains before working around the locomotive.
Jewelry can catch on equipment and cause injury,
or may short across an electrical circuit and cause
severe burns or electrical shock.
High voltage is used in the operation of equipment.
Do not be misled by the term LOW VOLTAGE.
Potentials as low as 50 volts may cause death.
1.
Open electrical equipment cabinet and set battery switch to OFF. Use a multimeter and perform a continuity test
on the engine compartment convenience receptacle. Replace defective parts.
REMOVAL
2.
Remove four screws (1) and receptacle cap (2).
3.
Remove two screws (3) and receptacle (4).
INSTALLATION
5.
Connect wires (6) and (7) to receptacle (4) and remove
tags. Install two screws (5).
6.
Install receptacle (4) and secure with two screws (3).
7.
Install receptacle cap (2) and secure with four screws
(1).
4-79