TM 55-2210-223-12
TO 45A2-2-14-41
Table 3-1. OPERATOR TROUBLESHOOTING (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10.
ENGINE STOPS WHILE IN OPERATION.
(cont)
Step 3.
Check to see if fuel pump light is lit.
Press fuel pump reset.
Step 4.
Check to see if fuel tank is empty.
WARNING
Fuel is very flammable and can explode easily. To
avoid serious injury or death, keep fuel away from
open fire and keep fire extinguisher within easy
reach when working with fuel. Do not work on fuel
system when engine is hot. Fuel can be ignited by
hot engine. Shut off engine and do not smoke while
refueling.
Fill fuel tank.
11.
ENGINE WILL NOT RESPOND TO THROTTLE.
Step 1.
Check to see if isolation switch is not in RUN position.
Set isolation switch to RUN position.
Step 2.
Check to see if GROUND light is lit.
Push GROUND RESET button.
Step 3.
Check to see if CONT switch is OFF.
Set CONT switch to ON.
12.
ENGINE WILL NOT SHUT OFF WHEN STOP BUTTON IS PUSHED IN.
Check to see if CONT switch is OFF.
Set CONT switch to ON.
3-7