TM 55-2210-223-34
TO 45A2-2-14-22
3-35. EXCITER-AUXILIARY GENERATOR ASSEMBLY (cont)
CLEANING, INSPECTION, AND REPAIR (cont)
26. Clean, inspect, and repair remaining parts by the following:
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do
not use near open flame or excessive heat. The flash point is 100 - 138°F (38 - 59°C). If you become
dizzy, get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes and
get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Do not direct
compressed air against skin. Use goggles or full face shield.
a.
Use drycleaning solvent and clean parts. Dry with compressed air.
b.
Inspect parts for cracks or breaks.
c.
Replace defective parts.
CAUTION
Do not paint gasket surfaces. Check that machined surfaces are not painted.
d.
Paint inside surface of covers with red insulating varnish and outside surface with gray gloss enamel.
TEST
27.
Refer to table 3-2 for exciter-auxiliary generator data.
3-127