TM 55-2210-224-34
3-37. MAIN GENERATOR (cont)
DISASSEMBLY
10. Use a punch and punch-mark fan (23) to armature head.
11. Cut lockwire from 16 capscrews (21) and remove capscrews and lockwashers (22). Use a puller and remove fan
(23).
12. Remove four capscrews (24) and lockwashers (25). Disconnect electrical leads from brush holders (29).
13. Remove four capscrews (26), lockwashers (27), and locking plates (28). Remove four brush holders (29).
14. Wrap a piece of insulation paper around the commutator to protect it while handling.
15. Remove three capscrews (30), lockwashers (31), and locking plate (32).
16. Use a puller and remove pulley (33) from armature shaft.
3-148