TM 55-2210-224-343-15.SERVICE METER GAGEThis task covers:a.Test b.Removal c.InstallationINITIALSETUPToolsTestEquipmentTool kit SC4940-97-CL-E12Variable dc voltage supplyREMOVALWARNING· Remove rings, bracelets, wristwatches, and neck chains before working around the locomotive.Jewelry can catch on equipment and cause injury, or may short across an electrical circuit and causesevere burns or electrical shock.· High voltage is used in the operation of equipment. Do not be misled by the term LOW VOLTAGE.Potentials as low as 50 volts may cause death.1.Open electrical equipment cabinet door and setbattery switch to OPEN.2.Tag and disconnect wires (1) and (2).3.Remove three nuts (3) and screws (4).4.Remove meter (5) from front of meter panel.3-50