TM 55-2210-224-34
3-13.
LOAD METER GAGES
This task covers:
a.
Test
b.
Removal
c.
Installation
INITIAL SETUP
Tools
Test Equipment
Tool kit SC4940-97-CL-E12
Variable dc voltage supply
REMOVAL
WARNING
· Remove rings, bracelets, wristwatches, and neck chains before working around the locomotive.
Jewelry can catch on equipment and cause injury, or may short across an electrical circuit and cause
severe burns or electrical shock.
· High voltage is used in the operation of equipment. Do not be misled by the term LOW VOLTAGE.
Potentials as low as 50 volts may cause death.
1.
Open electrical equipment cabinet door and set
battery switch to OPEN.
2.
Remove two nuts (1) and flat washers (2). Tag
and disconnect two electrical leads (3) from load
meter gage (7).
3.
Disconnect load meter gage light (4).
4.
Remove three nuts (5) and screws (6). Remove
load meter gage (7).
3-46