3-10.
DUPLEX AIR GAGES (cont)
TEST (cont)
ASSEMBLY
13.
Position gage face (13) in glass housing (16) and install two screws (15).
14.
Position glass cover (14) on gage face (13) and secure with copper clasp (12).
INSTALLATION
15.
Position duplex air gage (11) in control cabinet and install two lockwashers (10) and capscrews (9).
16.
Connect two air line connections (8) to duplex air gage (11).
17.
Position gasket (7) and cover (6) on control cabinet and install five capscrews (5).
18.
Install gasket (4), two gaskets (3), and front cover (2) and tighten six thumbscrews (1).
3-41