TM 55-2210-223-34
TO 45A2-2-14-22
3-36. MAIN GENERATOR (cont)
CLEANING, INSPECTION, AND REPAIR (cont)
57.
Clean, inspect, and repair ring assembly by the following:
a.
Check that insulation is not cracked or blistered. Replace damaged insulation.
b.
Check that fiberglass rings are not cracked or broken. Replace damaged fiberglass rings.
CAUTION
Do not paint gasket surfaces.
c.
Paint assembly with red insulating varnish.
58.
Clean, inspect, and repair remaining parts by the following:
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well-ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not
use near open flame or excessive heat. The flash point is 100-138°F (38-59°C). If you become dizzy,
get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes and get
medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Do not direct compressed
air against skin. Use goggles or full face shield.
a.
Use drycleaning solvent and clean parts. Dry with compressed air.
b.
Inspect parts for cracks or breaks.
c.
Replace defective parts.
d.
Paint the following with red insulating varnish:
CAUTION
Do not paint machined surfaces.
(1)
Fan
(2)
Inside surface of stator frame cover
(3)
Inside surface of main generator covers
3-144