TM 55-2210-223-34TO 45A2-2-14-223-36. MAIN GENERATOR (cont)CLEANING, INSPECTION, AND REPAIR (cont)CAUTIONDo not paint gasket surfaces.e.Paint the following with gray gloss enamel:(1)Coupler assembly(2)Inside surface of pulley(3)Outside surface of main generator covers(4)Outside surface of stator frame cover59.Refer to table 3-3 for main generator data.Table 3-3. Main GeneratorITEMSPECIFICATIONSafe speed1325 rpm maximumVoltage600 dcArmature amperes2600 ampsMain field amperes100 ampsNumber of brush arms8Brushes per arm4Brush size1 x 1-1/2 x 2-3/4 inches (25.4 x 38.1 x69.9 mm)Brush pressure7 to 8 pounds (3.2 to 3.6 kg)Brush-to-holder thickness clearance0.004 to 0.010 inch (0.10 to 0.25 mm)Brush-to-holder width clearance1/16 inch (1.5875 mm) maximumTEST60.Perform the armature and stator megohmmeter test by the following:NOTEA minimum of 500 V at 1 megohm is required for this test.a.Place lead (1) of megohmmeter (2) on shaft or core of armature (43).b.Place lead (3) of megohmmeter (2) on one of the commutator bars. Note reading on megohmmeter. Contacteach successive bar around the commutator.3-145