TM 55-2210-223-34
TO 45A2-2-14-22
3-11. LOAD METER GAGE
This task covers:
a.
Removal
b.
Test
c.
Installation
INITIAL SETUP
Tools
Tool kit SC 4940-97-CL-E12
Test Equipment
Variable dc voltage supply tester 6125-00-B06-6715
WARNING
Remove rings, bracelets, wristwatches, and neck chains before working
around the locomotive. Jewelry can catch on equipment and cause injury, or
may short across an electrical circuit and cause severe burns or electrical
shock.
High voltage is used in the operation of equipment. Do not be misled by the
term LOW VOLTAGE. Potentials as low as 50 volts may cause death.
REMOVAL
1.
Set battery switch to OPEN position.
2.
Tag electrical leads (3) and remove two nuts (1), four flat washers (2), and electrical leads from load meter
gage (4).
3.
Remove three nuts (5), lockwashers (6), screws (7), and lamp socket (8). Remove load meter gage (4).
3-45