TM 55-2210-223-34
TO 45A2-2-14-22
3-23. STARTING CONTACTOR
This task covers:
a.
Removal
c.
Cleaning
e.
Repair
g.
Installation
b.
Disassembly
d.
Inspection
f.
Assembly
h.
Test
INITIAL SETUP
Tools
Material/Parts
Tool kit SC 4940-97-CL-E12
Dry-cleaning solvent (Item 30, Appendix B)
Test Equipment
Multimeter 6625-01-139-2512
Variable dc voltage supply 6125-00-B06-6715
REMOVAL
WARNING
High voltage is used in the operation of equipment. Do not be misled by the term LOW VOLTAGE.
Potentials as low as 50 volts may cause death.
Remove rings, bracelets, wristwatches, and neck chains before working around the locomotive. Jewelry
can catch on equipment and cause injury, or may short across an electrical circuit and cause severe burns
or electrical shock.
1.
Set battery switch to OPEN position. Tag and disconnect wires from relay assembly.
2.
Remove two bolts (1), flat washers
(2), and relay assembly (3).
DISASSEMBLY
3.
Remove two screws (4), lockwashers
(5), and front cover (6).
4.
Remove four screws (7), lockwashers
(8), rear cover (9), and insulator
(10).
5.
Remove two screws (11) and lockwashers
(12) and remove lower contact base
(13).
3-70