TM 55-2210-223-34
TO 45A2-2-14-22
3-23. STARTING CONTACTOR (cont)
ASSEMBLY
23.
Install two guide pins (38) and secure with two lockwashers (37) and screws (36).
24.
Install spring washer (35), insulating washer (34), and coil (33) in coil assembly (28).
25.
Install stop core (32), lockwasher (31), and jamnut (30).
26.
Install insulating plate (29) on stationary contact assembly (16).
27.
Install stationary contact assembly (16) on coil assembly (28) and secure with four screws (27).
28.
Install four stationary contacts (26).
29.
Install movable contacts (25) in plunger (20) and secure with two springs (24), washers (23), and snaprings (22).
30.
Install spring (21) on plunger (20) and secure with plunger guide (19) and two screws (18).
31.
Install main spring (17) on plunger and main contact assembly (15).
32.
Install four arc boxes (14).
33.
Install lower contact base (13) and secure with two lockwashers (12), screws (11).
34.
Install insulator (10) and rear cover (9) and secure with four lockwashers (8) and screws (7).
35.
Install front cover (6), two lockwashers (5), and screws (4).
INSTALLATION
36.
Install relay assembly (3) and secure with two flat washers (2) and two bolts (1).
37.
Connect electrical wires to relay and remove tags.
3-74