TM 55-2210-224-12
4-42. AIR COMPRESSOR AIR CLEANER INTAKE
This task covers:
a.
Removal
c.
Cleaning
e.
Repair
g.
Installation
b.
Disassembly
d.
Inspection
f.
Assembly
INITIAL SETUP
Tools
Material/Parts
Tool kit SC4940-97-CL-E16
Drycleaning solvent (Item 23, Appendix E)
Lubricating oil (Item 14, Appendix E)
Rags (Item 20, Appendix E)
REMOVAL AND DISASSEMBLY
1.
Remove wingnut (1), flat washer (2), cork gasket (3),
and cover (4) and remove filter element (5) from base
(6). Remove base from elbow (7), if required.
CLEANING, INSPECTION, AND REPAIR
WARNING
Drycleaning solvent P-D-680 is toxic and
flammable. Wear protective goggles and
gloves and use only in a well-ventilated area.
Avoid contact with skin, eyes, and clothes and
don't breathe vapors. Do not use near open
flame or excessive heat. The flash point is 100
138°F (38 59°C). If you become dizzy, get fresh
air and medical aid immediately. If contact with
eyes is made, wash your eyes and get medical
aid immediately.
Compressed air used for cleaning purposes
will not exceed 30 psi (207 kPa). Do not direct
compressed air against skin. Use goggles or
full face shield.
2.
Clean cover (4) and base (6) with Drycleaning solvent.
Dry thoroughly with compressed air.
3.
Inspect filter element (5) for damage and serviceability.
4.
Repair consists of replacement of damaged parts.
4-103