TM 55-2210-224-34
3-24. POWER CONTACTOR (cont)
DISASSEMBLY (cont)
13. Disassemble interlock (28) by the following:
NOTE
All contacts are removed the same way. Only one
is called out.
a.
Remove nut (60), lockwasher (61), flat washer
(62), and contact finger (63).
b.
Remove screw (64), lockwasher (65), flat washer
(66), and contact support (67) from base (68).
CLEANING, INSPECTION, AND REPAIR
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear
protective goggles and gloves and use only in a well-ventilated
area. Avoid contact with skin, eyes, and clothes and don't breathe
vapors. Do not use near open flame or excessive heat. The flash
point is 100 - 138°F (38 - 59°C). If you become dizzy, get fresh air
and get medical aid immediately. If contact with eyes is made,
wash your eyes and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi
(207 kPa). Do not direct compressed air against skin. Use goggles
or full face shield.
14. Thoroughly clean parts with drycleaning solvent. Dry with compressed air.
3-92