TM 55-2210-224-34
3-26. GROUND RELAY (Cont)
DISASSEMBLY (cont)
9. Loosen calibrating screw locknut (49) and
calibrating
screw
(50)
and
unlock
calibrating spring (51) from 8, armature
(84).
10. Remove
two
capscrews
(52)
and
lockwashers (53). Remove interlock frame
(54).
11. Remove
two
machine
screws
(55),
lockwashers (56), and flat washers (57).
Remove outer contact block (58). Remove
two screws (59), lockwashers (60), flat
washers (61), and finger (62). Remove
screws (63), lockwashers (64), and contact
(65).
12. Remove
two
capscrews
(66)
and
lockwashers (67) and remove armature
stop (68).
13. Remove four screws (69), lockwashers
(70), and support (71). Remove nut (72),
lockwasher (73), flat washer (74), spacer
(75), contact (76), nut (77), lockwasher
(78), and stud (79).
14. Remove two screws (80), lockwasher (81), and flat washers (82). Remove contact (83) from armature (84).
15. Remove capscrew (85) and lockwasher (86). Remove operating coil (87) from magnet frame (88). Remove
magnet core (89).
3-107