TM 55-2210-224-34
3-26. GROUND RELAY (Cont)
DISASSEMBLY (cont)
7.
Remove two capscrews (25), lockwashers (26), and flat washers (27). Remove contactor (28) from base (29).
8. Remove two allenhead
screws (30), lockwashers
(31), and flat washers (32).
Remove allen-head screw
(33), lockwasher (34), and
flat washer (35). Remove
support blocks (36) and
(37). Remove nuts (38)
and (39), lockwashers (40)
and (41), flat washers (42)
and (43), normally open
contact (44), and normally
closed contact (45).
Remove spring retainer
(46), spring (47), and
movable contact finger
(48).
3-106