3-28. REVERSER (Cont)
DISASSEMBLY
CAUTION
All bus bars, cables, and contact mounting rods must be marked for proper installation before
removal from the reverser to prevent misapplication and subsequent electrical damage. Care must
be exercised in handling and storing the bus bars to prevent bending the copper.
4. Remove hose (8), elbow (9), pipe plug (10), nipple (11), tees (12) and (13), and nipples (14) and (15), and
adapter (16).
5. Remove two bolts (17), lockwashers (18), magnet valve assembly (19), and gasket (20). Refer to step 26 below
for disassembly of magnet valve assembly.
6. Remove two bolts (21), lockwashers (22), magnet valve assembly (23), and gasket (24). Refer to step 26 for
disassembly of magnet valve assembly.
7. Remove three screws (25),
lockwashers (26), two nuts (27), lockwashers (28), capscrews (29), and interlock (30).
8. Remove tension spring (31) and cotter pin (32). Remove nut (33), lockwasher (34), bolt (35), and pawl assembly
(36).
9. Loosen locknut (37) and remove setscrew (38) with locknut and lockwasher (39).
10. Remove operating lever assembly (40) and woodruff key (41).
3-115