TM 55-2210-224-34
4-8.
AIR COMPRESSOR ASSEMBLY
This task covers:
a.
Disassembly
c.
Inspection
e.
Assembly
b.
Cleaning
d.
Repair
f.
Test
INITIAL SETUP
Tools
Material/Parts
Tool Kit SC4940-97-CL-E12
Dry ice (Item 10, Appendix B)
Magnetic particle tester
Drycleaning solvent (Item 34, Appendix B)
6635-00-306-6568
Lubricating oil (Item 21, Appendix B)
Feeler gage
Grease BB (Item 14, Appendix B)
Honing drill
Dial indicator 5210-00-640-0953
Test Equipment
Torque wrench
Orifice holder
Induction heater
Micrometer 5210-00-267-3093
Equipment Condition
Reference
Condition Description
Para 3-42
Air compressor assembly removed
DISASSEMBLY
WARNING
· Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use only in a well-ventilated area. Avoid contact with skin, eyes,
and clothes and don't breathe vapors. Do not use near open flame or excessive
heat. The flash point is 100 138°F (38 59°C). If you become dizzy, get fresh air
and medical aid immediately. If contact with eyes is made, wash your eyes and
get medical aid immediately.
· Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).
Do not direct compressed air against skin. Use goggles or full face shield.
·
NOTE
Thoroughly clean exterior to prevent dirt from entering internal parts. 1.
Use drycleaning solvent and remove dirt from exterior of air compressor.
Dry with compressed air.
4-9