TM 55-2210-223-24
TO 45A2-2-14-22
3-30. BATTERY CHARGING AMMETER SHUNT
This task covers:
a.
Removal
b.
Test
c.
Installation
INITIAL SETUP:
Tools
Tool kit SC 4940-97-CL-E12
Multimeter 6625-01-139-2512
REMOVAL
WARNING
High voltage is used in the operation of equipment. Do not be misled by the term LOW VOLTAGE.
Potentials as low as 50 volts may cause death.
Remove rings, bracelets, wristwatches, and neck chains before working around the locomotive.
Jewelry can catch on equipment and cause injury, or may short across an electrical circuit and cause
severe burns or electrical shock.
1.
Place battery switch in OPEN position.
2.
Tag and disconnect positive lead from battery.
3.
Remove eight bolts (1) and lockwashers (2) and lower rear access panel (3).
4.
Remove locknut (4), nut (5), and lockwasher (6).
5.
Tag and disconnect wires (7), (8), (9), and (10).
6.
Remove flat washer (11).
7.
Remove two screws (12), lockwashers (13), and flat washers (14). Remove wires (15).
8.
Remove shunt (16).
9.
Remove bolt (17).
3-104