TM 55-2210-223-24
TO 45A2-2-14-22
3-36. MAIN GENERATOR
This task covers:
a.
Removal
c.
Cleaning
e.
Repair g.
Assembly
b.
Disassembly
d.
Inspection
f.
Test
h.
Installation
INITIAL SETUP:
Tools
Material/Parts
Tool kit SC 4940-97-CL-E12
Drycleaning solvent (Item 30, Appendix B)
Mica undercutter
Grease (Item 12, Appendix B)
Dial indicator 5210-00-640-0953
Clear acrylic lacquer (Item 17, Appendix B)
Crankshaft deflection strain gauge
Red insulating varnish (Item 33, Appendix B)
Model #696 5210-00-494-1776
Gray gloss enamel (Item 9, Appendix B)
Portable propane torch
Electrical tape (Item 32, Appendix B)
3439-00-542-0531
Insulating paper (Item 26, Appendix B
Induction heater 2815-00-366-1432
Wiping Rags (Item 28, Appendix B)
Puller set
Test Equipment
Personnel Required
Multimeter 6625-01-139-2512
3
Megohmmeter 6625-00-456-7442
Equipment Condition
Reference
Condition Description
Para 3-7
Hood removed
TM 55-2210-223-12
Blower motor belts removed
TM 55-2210-223-12
Drive belts removed
Para 3-35
Exciter-auxiliary generator removed
REMOVAL
WARNING
Remove rings, bracelets, wristwatches, and neck chains before working around the locomotive.
Jewelry can catch on equipment and cause injury, or may short across an electrical circuit and cause
severe burns or electrical shock.
High voltage is used in the operation of equipment. Do not be misled by the term LOW VOLTAGE.
Potentials as low as 50 volts may cause death.
1.
Set battery switch to open position.
3-133