TM 55-2210-223-34
TO 45A2-2-14-22
3-36. MAIN GENERATOR (cont)
REMOVAL (cont)
NOTE
If repair of main generator is limited to resurfacing commutator, refer to step 54f(l) below.
2.
Remove two covers (1).
3.
Remove four bolts (2), lockwashers (3), and cover (4).
4.
Remove eight locknuts (5), four spacers (6), and eight bolts (7) and remove flexible coupling (8).
5.
Tag and disconnect terminals (9).
6.
Remove two screws (10), nuts (11), clamp (12), and conduit (13).
7.
Use a punch and punch-mark main generator to engine flywheel. Remove 16 bolts (14) and lockwashers (15).
8.
Remove four base mounting bolts (16), washers (17), (18), and (19), four nuts (20), and two dowel pins (21).
3-134