TM 55-2210-224-12
4-19. ELECTRICAL EQUIPMENT CABINET DOOR (cont)
DISASSEMBLY (cont)
5.
Remove two screws (12), lockwashers (13), and spring (14) from latch lever (10).
6.
If necessary, drill out spot welds and remove two hinge halves (15).
CLEANING, INSPECTION, AND REPAIR
WARNING
Drycleaning solvent P-D-680 is toxic and
flammable. Wear protective goggles and gloves
and use only in a well-ventilated area. Avoid
contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or
excessive heat. The flash point is 100 - 138°F
(38 - 59°C). If you become dizzy, get fresh air
and medical aid immediately. If contact with
eyes is made, wash your eyes and get medical
aid immediately.
Compressed air used for cleaning purposes will
not exceed 30 psi (207 kPa). Do not direct
compressed air against skin. Use goggles or
full face shield.
7.
Clean parts with drycleaning solvent and dry with compressed air.
8.
Inspect parts for cracks, breaks, and damage.
9.
Inspect lock and handle for serviceability.
10.
Repair damaged parts by straightening or welding. Grind welds smooth. Paint repaired areas.
ASSEMBLY
11.
If removed, weld two hinges halves (15) on door (2).
12.
Position spring (14) on latch bar (5) and install two lockwashers (13) and screws (12).
13.
Install handle (11) in door (2) and position latch lever (10) on handle shaft.
14.
Install flat washer (9), nut (8), and cotter pin (7).
15.
Position latch bar (5) in guide loops (6) and on latch lever (10) and install flat washer (4) and spring (3).
INSTALLATION
16.
Position door (2) on electrical equipment cabinet and install two pins (1).
4-50