TM 55-2210-224-34
3-8.
SAFETY WARNING BELL OPERATING VALVE (cont)
REMOVAL
5.
Disconnect three air line fittings (4).
6.
Remove two capscrews (5), lockwashers (6), and
operating valve (7).
7.
Remove three adapters (8).
INSTALLATION
8.
Apply antiseize tape to the threads of three
adapters (8) and install adapters in operating
valve (7).
9.
Position operating valve (7) in control cabinet and
install two lockwashers (6) and capscrews (5).
10.
Connect three air line fittings (4).
11.
Perform steps 1, 3 and 4 above.
12.
Position gasket (3) and cover (2) on control cabinet and installeight screws (1).
3-35