TM 55-2210-223-34
TO 45A2-2-14-22
3-18. BATTERY CHARGING RECEPTACLE
This task covers:
a.
Test
d.
Cleaning
g.
Test
b.
Removal
e.
Inspection
h.
Assembly
c.
Disassembly
f.
Repair
i.
Installation
INITIAL SETUP
Tools
Test Equipment
Tool kit SC 4940-97-CL-E12
Multimeter 6625-01-139-2512
Megohmmeter 6625-00-456-7442
TEST
WARNING
High voltage is used in the operation of equipment. Do not be misled by the
term LOW VOLTAGE. Potentials as low as 50 volts may cause death.
Remove rings, bracelets, wristwatches, and neck chains before working
around the locomotive. Jewelry can catch on equipment and cause injury, or
may short across an electrical circuit and cause severe burns or electrical
shock.
1.
Set battery switch to OPEN position.
2.
Disconnect battery leads.
3.
Use a multimeter and perform a continuity test on the battery charging receptacle.
4.
Use a megohmmeter and perform a resistance test on the battery charging receptacle.
REMOVAL
5.
Disconnect positive lead from battery.
6.
Remove four bolts (1) and remove receptacle assembly (2) from firewall.
3-57