TM 55-2210-224-34
3-19.
MULTIPLE-UNIT RECEPTACLE
This task covers:
a.
Removal
c.
Cleaning
e.
Repair
g.
Assembly
b.
Disassembly
d.
Inspection
f.
Test
h.
Installation
INITIAL SETUP
Tools
Material/Parts
Tool kit SC4940-97-CL-E12
Drycleaning solvent (Item 34, Appendix B)
REMOVAL
WARNING
· High voltage is used in the operation of equipment. Do not be misled by the term LOW VOLTAGE.
Potentials as low as 50 volts may cause death.
· Remove rings, bracelets, wristwatches, and neck chains before working around the locomotive.
Jewelry can catch on equipment and cause injury, or may short across an electrical circuit and cause
severe burns or electrical shock.
· Use caution when removing cover hinge shaft. Spring is under pressure and may cause injury to
personnel when released from cover hinge shaft.
1.
Open electrical equipment cabinet door and set battery switch to OPEN.
3-58