TM 55-2210-224-34
3-19.
MULTIPLE-UNIT RECEPTACLE (cont)
CLEANING, INSPECTION, AND REPAIR (cont)
12.
Inspect pins (17) for pitted or burned areas.
13.
Inspect receptacle housing (19) for bends or dents.
14.
Inspect for brokenor frayed wiring.
15.
Inspect for broken or cracked insulation plates.
16.
Repair consists of replacement of damaged parts.
TEST
17.
Use a multimeter and perform a continuity test on the multiple-unit receptacle.
18.
Use a megohmmeter and perform a resistance test on the multiple-unit receptacle.
ASSEMBLY
19.
Install insulator plate (18), if removed, in receptacle housing (19).
20.
Install 16 pins (17), connect wires to pins, and remove tags.
21.
Install insulator plate (16).
22.
Position pin assembly (15) in receptacle housing (19) and install three screws (14).
23.
Position housing cover (13) and spring (12) on receptacle housing (19) and install cover hinge shaft (11) and
external snapring (10).
INSTALLATION
24.
Position multiple-unit receptacle (9) on box (6) and install three lockwashers (8) and capscrews (7).
25.
Connect electrical leads to terminal board inside box (6) and remove tags.
26.
Position gasket (5) and cover (4) on box (6) and install eight flat washers (3), lockwashers (2),nd capscrews (1).
27.
Close electrical equipment cabinet door.
3-61