TM 55-2210-224-34
3-19.
MULTIPLE-UNIT RECEPTACLE (cont)
DISASSEMBLY
5.
Remove external snapring (10), cover hinge shaft
(11), spring (12), and housing cover (13).
6.
Remove three screws (14) securing pin assembly
(15) to receptacle housing (19).
7.
Remove pin assembly (15) from receptacle
housing (19).
8.
Remove insulator plate (16).
9.
Tag and disconnect wires from 16 pins (17) and
remove pins as required.
10.
Remove insulator plate (18), if required, from
receptacle housing (19).
CLEANING, INSPECTION, AND REPAIR
WARNING
· Drycleaning solvent P-D-680 is toxic
and
flammable.
Wear
protective
goggles and gloves and use only in a
well-ventilated area. Avoid contact with
skin, eyes, and clothes and don't
breathe vapors. Do not use near open
flame or excessive heat. The flash
point is 100 - 138°F (38 - 59°C). If you
become dizzy, get fresh air and get
medical aid immediately. If contact
with eyes is made, wash your eyes and
get medical aid immediately.
· Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Do not direct compressed air
against skin. Use goggles or full face
shield.
11.
Use a cloth dampened in drycleaning solvent and
clean parts. Dry with compressed air.
3-60